BIO PLUS®Laminar Benches

Home Feedback Page Downloads & Printing Links

Up

Ultra High Performance
Laminar Flow Bench

The cleanest flow bench in the industry - better than class 1.
Typically zero particles per liter bigger than 5 nanometers
Technovation Laminar Flow Bench

 

Features: Benefits:
  • Double HEPA filtration system- 99.999999% efficiency 
  • BIO PLUS® Bactericidal primary HEPA filter
  • Low pressure drop 
  • Low turbulence design with perforated top and front cover
  • High tech composite material
  • Better than class 1 -virtually particle free
  • No growth or shedding of bacteria with time
  • Low noise/power ratio  -lifetime terminal HEPA filter 
  • Inhibits entrainment of particles from outside -in use class 1 performance

  • Clean high tech look in off-white color  

 

Technovation offers two types of Mail Opening Benches:

VF SERIES: These units have double HEPA filtration with 0.1-0.3 Um efficiency of 99.999999% and are recommended for most of the mail applications where protection against virtually all bio-pathogens and potent chemicals is desired.

VF100 SERIES: These units have single HEPA/ULPA filtration only.

Other Options:  

  • Adjustable Front Cover
  • Standard Perforated Polypropylene Top
  • Perforated Stainless Steel Top
  • Perforated Aluminum Top  


Specifications:
 

(Larger Image)

(Printable Version- )

Nominal Dimensions (Inches- Centimeters)

Model

A

B

C

D

E

VF-2.5

32 - 81

46 - 117

26 - 66

24 - 61

4 - 10

VF-4

48 - 122

85 - 216

28 - 71

24 - 61

32 - 81

VF-6

72 - 183

85 - 216

28 - 71

24 - 61

32 - 81

VF-8

96 - 244

85 - 216

28 - 71

24 - 61

32 - 81

VF100-4

50 - 127

72 - 183

26 - 66

24 - 61

32 - 81

VF100-6

74 - 188

72 -183

26 - 66

24 - 61

32 - 81

VF100-8

98 - 249

72 - 183

26 - 66

24 - 61

32 - 81

Electrical And Flow  All models are single phase 50/60 Hz. All units have 2 speeds of operation.

 

Light # 

Watts

Option A*

Option B*

Flow Velocity

Model

Wattage

Fan

Fan V/A/A

Fan V/A/A

 FPM- M/S

VF-2.5

1/30W

270

208-230/1.2/2

115/2.5/5

[60-112] - [0.3-0.55]

VF-4

1/30W

270

208-230/1.2/2

115/2.5/5

[60-112] - [0.3-0.55]

VF-6

1/45W

270

208-230/1.2/2

115/2.5/5

[60-80] - [0.3-0.4]

VF-8

2/60W

540

208-230/2.5/5

115/5/10

[60-112] - [0.3-0.55]

VF100-4

1/30W

270

208-230/1.2/2

115/2.5/5

[60-134] - [0.3-0.66]

VF100-6

1/45W

270

208-230/1.2/2

115/2.5/5

[60-96] - [0.3-0.48]

VF100-8

2/60W

540

208-230/2.5/5

115/5/10

[60-134] - [0.3-0.66]

*Volts/Normal Max amperage/ Recommended Circuit Breaker amperage. All units require 115 VAC for lights. For non US power requirements specify Option C.

 