BIO PLUS®3000 Series

Home Feedback Page Downloads & Printing Links

Up
3001A
3001X

3000 Series 
Compact Series In-Duct Bactericidal* 99.9% @ 0.3 Um  Filters


Electrically Enhanced Filtration** (EEF)

 

Engineering/Application Data.
 

Electrically Enhanced Filters (EEF)

Cleanrooms: New, Upgrades &
Conversions

 Mini Environment

Isolators

 Flow Rates from 750-10,000 scfm

Highly Compact Units

Click to see larger picture
(Printable Version- )

 

Features:

Benefits:

  • Bactericidal – traps and kills bacteria due to ionizing radiation.
  • HEPA level filtration – each individual filter/housing is tested.
  • Small size/lower weight – easily installs ceiling space.
  • Independent flow velocity/distribution control 
     –supply where needed.
  • Quick filter changes done outside room.
  • Connects to conventional A/C units – low weight.
  • No plenum required – leaks eliminated.
  • Remote on-off, control/indicators.
  • Easily ducted for negative pressure.
  • Lower bio burden – inhibits growth through filter and bacteria shedding.
  • High reliability – class 7-9 without terminal HEPAs.
  • Lower installation cost.
  • Higher and more effective room coverage at a given flow rate.
  • No contamination during filter changes.
  • Lower initial cost – roof reinforcements may not be required.
  • Lower initial cost – less leakage.
  • Ease of control and monitoring.
  • Ideal for hospital and other isolators.

SERIES 3000 MODELS

Model Description # of 
Filters
Max. Flow scfm (m3/h)

Overall Size in.(cm) W*H*D

3001X

With small single phase fan

1 1200 (2125) 32(81) x 26(66) x 16(41)
3001A Without fan 1 2000 (3400) @ 1” WC 32(81) x 26(66) x 16(41)
3001B With high flow 3 phase fan 1 3000 (5100) 32(81) x 26(66) x 31(79)
3004A Without fan 4 8000 (13,600) @ 1”WC 64(162) x 52(132) x 16(41)
3004B

With high flow 3 phase fan

4 10,000 (17,000) 64(162) x 52(132) x 36 (91
  • Use as primary filter with terminal HEPA filters for class 1 -5.

  • Use as final filter with supply diffusers for class 6 - 8 .

  • Series 3000 units can be conveniently ducted so as to create negative pressure rooms/isolators.  

* Based on independent laboratory testing using Escherichia coli and Staphylococcus epidermidis.
** Patented, April 1995, US Patent 5,403,383.

 